Share this post on:

Limits 10 times higher (or five occasions higher in the case of sodium salicylate addition) than the LSC-radon technique for precisely the same measurement occasions. The all round comparison from the positive aspects and disadvantages of all presented solutions could be summarized within the conclusions presented in Table 5.Table five. Characteristic parameters for the presented procedures (the untreated water samples). Cherenkov Counting Sample volume [mL] Counting time [min] MDA [Bq/L] three 20 300 1 (original system) 0.five (with 1 g sodium salicylate) Gamma Spectrometry 450 1200 0.45 LSC-Radon three 10 300 0.four. Discussion Cherenkov’s counting technique delivers satisfactory precision with deviations 20 . In its original type, it can be a uncomplicated, non-expensive and non-destructive strategy that provides reliable 226 Ra screening in small-volumes water samples through LS counter. The purpose of this paper was to explore the Cherenkov counting strategy around the Quantulus detector and the most important parameters (efficiency, Tenidap Epigenetics detection limit, reliability and precision) with the method. Nevertheless, by far the most vital drawback happens when the sample includes other radionuclides besides 226 Ra that could make the Cherenkov spectrum, in which case, the interferences appear inside the generated spectra, and chemical pretreatment is necessary just before the counting. Further investigation should really handle the possible presence of 40 K in groundwater (and, consequently, in drinking water) that can produce Cherenkov radiation and as a result interfere using the 226 Ra spectrum. A preconcentration step coupled with chemical separation needs to be carried out prior to counting to remove naturally occurring radionuclides, 40 K or progenies from U and Th series [10]. A different drawback is definitely the lengthy counting time of 1000 min if endeavoring to reach the acceptable MDA parameter. Even so, the addition of 1 g of sodium salicylate guarantees that detection limits under those legally permittedcan be reached inside 300 min of counting. The investigation presented within this paper demonstrated that repeatable outcomes are obtainable within the case of sodium salicylate addition. Gamma spectrometry can be a non-destructive and direct approach that offered measurements of 226 Ra content that were not reliable in higher activity concentrations (for C(226 Ra) ten Bq/L). Its MDA is decrease than the limit permitted by the legislation in Serbia [6], nevertheless it demands 20 h of measurement to attain it. Alternatively, the LSC-EPA 913.0 method gave acceptable results on all 226 Ra activity concentrations examined. This technique is very straightforward, nevertheless it is destructive, because the sample is mixed with a scintillation cocktail. Pretty low detection limits can be achieved through measurements, which correspond to critical levels determined in studies [2] that influence human overall health. Precise and reliable benefits, the smaller sample volume needed for the evaluation and low MDA values make the LSC-radon strategy the most sufficient among all these presented for health-related study, epidemiologic research and the dose assessment of drinking water. 5. Conclusions Cherenkov counting method for 226 Ra determination in water was optimized on a Quantulus LS counter. The approach was uncomplicated, rapid, and MCC950 Inhibitor economical. To date, the literature has not supplied data around the Cherenkov counting strategy for 226 Ra determination on Quantulus. Consequently, the presented analysis enabled the assessment in the method’s possible in the field of routine radiological evaluation of samples. The obtained detection efficiency was 15.87 (two.

Share this post on:

Author: M2 ion channel